Features: 
 Large LC Display with backlight
 High accuracy
 Fast response
 Measures environment/dewpoint/wetbulb temperature simutaneously
 Internal memory: 99 groups of data
 Temperature unit: °C & °F selectable
 MAX/MIN
Data hold
Auto power off
 Supper low power consumption
 External 9V DC power supply
 Data logging and USB interface


Specifications:

Temperature range: -20~60°C(-4~140°F)
Basic accuracy: ±0.5 °C (±1.0 °F)
Resolution: 0.01°C/°F
Sampling rate: 3 times per second
Relative humidity range: 0~100%RH
Basic accuracy: ±2.0 % RH
Resolution: 0.1%RH
Response time: <10S (90% 25℃)
Type-k temperature range: -100~1372°C(-148~2501°F
Accuracy: ± (1% ±1°C)
Resolution: 0.01°C/°F,0.1°C/°F,1°C/°F
Wetbulb range: -20 ~ 60 °C(-4 ~ 140 °F)
Dewpoint range: -50 ~ 60 °C(-58 ~ 140 °F)
Internal memory: 99 groups of data
Power: 1*9V battery, or 9V DC
Data logger memory: 32000 data
Operation condition: 0 ~ 40°C,< 80% RH non-condensing
Storage condition: -10~ 60°C,<80% RH non-condensing
Weight: 200g
Dimension: 215mm*58mm*33mm

Saler Company Information

Company : Shenzhen Leeder Measurement & Control Technology Co., Ltd
Phone : 008675585298089
More Information : View
Online order registration form
No comments have been posted yet
loading
Your comment has been sent
Temperature and Humidity Meter with Data Logger

Features: 
 Large LC Display with backlight
 High accuracy
 Fast response
 Measures environment/dewpoint/wetbulb temperature simutaneously
 Internal memory: 99 groups of data
 Temperature unit: °C & °F selectable
 MAX/MIN
Data hold
Auto power off
 Supper low power consumption
 External 9V DC power supply
 Data logging and USB interface


Specifications:

Temperature range: -20~60°C(-4~140°F)
Basic accuracy: ±0.5 °C (±1.0 °F)
Resolution: 0.01°C/°F
Sampling rate: 3 times per second
Relative humidity range: 0~100%RH
Basic accuracy: ±2.0 % RH
Resolution: 0.1%RH
Response time: <10S (90% 25℃)
Type-k temperature range: -100~1372°C(-148~2501°F
Accuracy: ± (1% ±1°C)
Resolution: 0.01°C/°F,0.1°C/°F,1°C/°F
Wetbulb range: -20 ~ 60 °C(-4 ~ 140 °F)
Dewpoint range: -50 ~ 60 °C(-58 ~ 140 °F)
Internal memory: 99 groups of data
Power: 1*9V battery, or 9V DC
Data logger memory: 32000 data
Operation condition: 0 ~ 40°C,< 80% RH non-condensing
Storage condition: -10~ 60°C,<80% RH non-condensing
Weight: 200g
Dimension: 215mm*58mm*33mm

Saler Company Information

Company : Shenzhen Leeder Measurement & Control Technology Co., Ltd
Phone : 008675585298089
More Information : View
Online order registration form