AAS atomic absorption spectrometer for trace metal elements analysis
AAS atomic absorption spectrometer for trace metal elements analysis
  • Seen : 86 View

0
AAS atomic absorption spectrometer for trace metal elements analysis

1. Build-in computer data processing and LCD: adopting highly integrated micro digital circuit, which is stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuteriumlamp and background, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.

 

2. Good basic line stability: Double-beam system of optimized design can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.

The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.

 

3. High precision of measurement: Gas path system is equipped with precision pressure stabilizing andcurrent Stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passesthrough the flame to ensure a high precision analytical test and low characteristic concentration

 

4. Optical path of high energy: A total reflection system is adopted to eliminate color difference in full range.

By means of chemical conversion, a round light spot of the light source becomes a long light spot, whichenters into the slit. The light flux of double beam is enhanced.

 

5. Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water- cooling.

 

6. Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic

absorption and hydride generation.

 

7. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame.

Saler Company Information

Company : Chongqing Kolery Trading Co., Ltd
Phone : 008617830406332
More Information : View
Online order registration form
No comments have been posted yet
loading
Your comment has been sent
AAS atomic absorption spectrometer for trace metal elements analysis

1. Build-in computer data processing and LCD: adopting highly integrated micro digital circuit, which is stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuteriumlamp and background, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.

 

2. Good basic line stability: Double-beam system of optimized design can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.

The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.

 

3. High precision of measurement: Gas path system is equipped with precision pressure stabilizing andcurrent Stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passesthrough the flame to ensure a high precision analytical test and low characteristic concentration

 

4. Optical path of high energy: A total reflection system is adopted to eliminate color difference in full range.

By means of chemical conversion, a round light spot of the light source becomes a long light spot, whichenters into the slit. The light flux of double beam is enhanced.

 

5. Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water- cooling.

 

6. Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic

absorption and hydride generation.

 

7. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame.