Laboratory oven with 1200 ℃ volume of 4 liters
Laboratory oven with 1200 ℃ volume of 4 liters
  • Seen : 545 View

0
Laboratory oven with 1200 ℃ volume of 4 liters

applications:

General laboratory, food industry, chemical, pharmaceuticals, ash

Advantages:

In the Mafel furnaces of SiC type:

High shocks and high SiC corrosion resistance increase the strength and durability of the enclosure.
Due to the high thermal conductivity of SiC, a good coherent thermal enclosure is created in the whole.
By conducting heat from heat-to-SiC layer elements, the radiation level is wider, the heating rate of the same electric power is significantly increased.
In ovens such as Mafel SiC, in contrast to the Mafell furnaces, the curing unit can be completely independent.

Technical Specifications:

Maximum temperature: 1200 ℃
Maximum operating temperature: 1100 ℃
Useful dimensions of the furnace's heating chamber: (cm3) 16 × 13 × 17 ≡ Depth × Height × Width
Inlet dimensions of the furnace span: (cm2) 14 × 11.5 ≡ height × width
Heat Chamber Type: Mafel (Items not visible)
Upholstery: Ceramic-ceramic composite bodies based on α-SiC
High temperature uniformity in the chamber
Thermal Element: Al-Cr-Fe Alloy
Thermocouple: Ni-Cr-Ni, Type K, equipped with ceramic pods
External dimensions of the furnace: (cm3) 39 × 56 × 37 ≡ Depth × height × width
Furnace weight 15 kg (This small and lightweight grill is designed to be turned on the desk and is easily removable.)
Maximum power consumption in heating mode (kW) is 1.5. The power required to stabilize the temperature at 1000 ℃ (kW) is reduced to 0.6.
The furnace is equipped with a protective microswitch on the door.
The furnace works with single-phase electricity and the maximum current is 7 amps.
The temperature control system is a precise PID type and allows temperature stabilization of up to ± 2 ° C.
The furnace is equipped with a digital temperature display and the temperature setting required from the device is carried out digitally.
The furnace control is controlled by the thyristor switch. In addition, an electromechanical contactor is also provided as a shield that will cut off the entire system if it occurs.
In case of any problems with the thermocouple and thyristor switch, the control system automatically turns off the furnace and displays the problem.
The system is designed to protect against overheating and opening the thermocouple spot.
On request, a single-bridging control system, multi-bridges with computer monitoring capabilities, timers, chimneys, floor protectors, etc. SiC can be installed on the furnace.

Saler Company Information

Company : Exciton
More Information : View
Online order registration form
No comments have been posted yet
loading
Your comment has been sent
Laboratory oven with 1200 ℃ volume of 4 liters

applications:

General laboratory, food industry, chemical, pharmaceuticals, ash

Advantages:

In the Mafel furnaces of SiC type:

High shocks and high SiC corrosion resistance increase the strength and durability of the enclosure.
Due to the high thermal conductivity of SiC, a good coherent thermal enclosure is created in the whole.
By conducting heat from heat-to-SiC layer elements, the radiation level is wider, the heating rate of the same electric power is significantly increased.
In ovens such as Mafel SiC, in contrast to the Mafell furnaces, the curing unit can be completely independent.

Technical Specifications:

Maximum temperature: 1200 ℃
Maximum operating temperature: 1100 ℃
Useful dimensions of the furnace's heating chamber: (cm3) 16 × 13 × 17 ≡ Depth × Height × Width
Inlet dimensions of the furnace span: (cm2) 14 × 11.5 ≡ height × width
Heat Chamber Type: Mafel (Items not visible)
Upholstery: Ceramic-ceramic composite bodies based on α-SiC
High temperature uniformity in the chamber
Thermal Element: Al-Cr-Fe Alloy
Thermocouple: Ni-Cr-Ni, Type K, equipped with ceramic pods
External dimensions of the furnace: (cm3) 39 × 56 × 37 ≡ Depth × height × width
Furnace weight 15 kg (This small and lightweight grill is designed to be turned on the desk and is easily removable.)
Maximum power consumption in heating mode (kW) is 1.5. The power required to stabilize the temperature at 1000 ℃ (kW) is reduced to 0.6.
The furnace is equipped with a protective microswitch on the door.
The furnace works with single-phase electricity and the maximum current is 7 amps.
The temperature control system is a precise PID type and allows temperature stabilization of up to ± 2 ° C.
The furnace is equipped with a digital temperature display and the temperature setting required from the device is carried out digitally.
The furnace control is controlled by the thyristor switch. In addition, an electromechanical contactor is also provided as a shield that will cut off the entire system if it occurs.
In case of any problems with the thermocouple and thyristor switch, the control system automatically turns off the furnace and displays the problem.
The system is designed to protect against overheating and opening the thermocouple spot.
On request, a single-bridging control system, multi-bridges with computer monitoring capabilities, timers, chimneys, floor protectors, etc. SiC can be installed on the furnace.

Saler Company Information

Company : Exciton
More Information : View
Online order registration form