Automatic External Defibrillator
Automatic External Defibrillator
  • Seen : 236 View

0
Automatic External Defibrillator

FEATURE

Three-step defibrillation process

Two-button operation

Extensive voice and visual prompts for the operator

Continuous event recording for reporting each use to a printer or computer

Weekly self-test to ensure readiness

Biphasic energy output

Lock-out protection to prevent inadvertent defibrillation


SPECIFICATION

Defibrillator

Output: Biphasic Truncated exponential

Energy Sequence: 150, 150, 200J

Charge Time: 8 sec. to150J

10 sec. to 200 J(NEW battery)

Analysis Time: 9 sec.

The maximum time from the initation of rhythm analysis to readiness for discharge with a new battery: Less than 30 seconds

The maximum time from the initation of rhythm analysis to readiness for discharge after 6 shocks: Less than 35 seconds


The maximum time from the initation of rhythm analysis to readiness for discharge: Less than 25 seconds

Audible Prompts: 20 audible prompts

Visual Prompts: LED prompts

Controls: Two buttons - On/Off, Shock

Output Energy Accuracy: ±15% into impendance from 25 to 75Ω

The Maximum Voltage: 1200±50V

Output disabled when the patient impedance is outside limits: 20Ω to 200 Ω


Battery

Part No: CR123A-4X2

Non-Rechargeable: 12V DC. 3.0 Ah

Capacity: 100 discharges at 200 Joules or 120 discharges at 150 Joules

Shelf Life (25℃±15℃): 10 years (5 years storage + 5 years standby)

5 years standby (after installation)

Saler Company Information

Company : Anjue Medical Equipment Co., Ltd
Phone : 00865565836185
More Information : View
Online order registration form
No comments have been posted yet
loading
Your comment has been sent
Automatic External Defibrillator

FEATURE

Three-step defibrillation process

Two-button operation

Extensive voice and visual prompts for the operator

Continuous event recording for reporting each use to a printer or computer

Weekly self-test to ensure readiness

Biphasic energy output

Lock-out protection to prevent inadvertent defibrillation


SPECIFICATION

Defibrillator

Output: Biphasic Truncated exponential

Energy Sequence: 150, 150, 200J

Charge Time: 8 sec. to150J

10 sec. to 200 J(NEW battery)

Analysis Time: 9 sec.

The maximum time from the initation of rhythm analysis to readiness for discharge with a new battery: Less than 30 seconds

The maximum time from the initation of rhythm analysis to readiness for discharge after 6 shocks: Less than 35 seconds


The maximum time from the initation of rhythm analysis to readiness for discharge: Less than 25 seconds

Audible Prompts: 20 audible prompts

Visual Prompts: LED prompts

Controls: Two buttons - On/Off, Shock

Output Energy Accuracy: ±15% into impendance from 25 to 75Ω

The Maximum Voltage: 1200±50V

Output disabled when the patient impedance is outside limits: 20Ω to 200 Ω


Battery

Part No: CR123A-4X2

Non-Rechargeable: 12V DC. 3.0 Ah

Capacity: 100 discharges at 200 Joules or 120 discharges at 150 Joules

Shelf Life (25℃±15℃): 10 years (5 years storage + 5 years standby)

5 years standby (after installation)