Small Oxygen Plant
  • Seen : 291 View

0
Small Oxygen Plant

Advantage
1. Especally designed for clinics and small hospitals up to100 beds.
2. Small size and occupy small area
3. Easy installation.
4. The design is made for 24/7 operation.It is a strong system.
5. Convenient maintenance and low maintenance cost.
6. Equipped with automatic start&stop function.Safer and more reliable design.Humanization design. More longer equipment life.
7. Total oil free system, safer and healthier.
8. Easy operation.
9. Economic system to meet small hospitals low investment requirement

How to calculate what kinds of system a hospital needs?
All solutions depending on we know about the hospital requirement very well.
For example, how many patient beds? if there is ventilator or anesthesia machine?
After we learn about these information, we can provide a solution with below formula.
- An ordinary hospital bed requires 3L of oxygen with pressure within 1 bar/0.1Mpa, and 60% utilization.
- If it is an ICU bed, each bed needs 5L with pressure within 1 bar/0.1Mpa, 100% utilization
- One anesthesia machine with 20L oxygen under pressure 4bar /0.4Mpa;
- One ventilator with 10L oxygen under pressure 4bar /0.4Mpa.
- For cylinder filling. we count it as 24 hrs working continuously and the cylinder tank 40L(150bar).
For example, an JAY-60 can fufill 12 cyliners in 24 hrs.
We count it as 40L *150 bar / 60L =100min. It takes approximately 2 hrs to fufill 1 tank.

Below are some of our solutions, we can customize solution according to your actual requirement

Saler Company Information

Company : Pioway Medical Lab Equipment Co., Ltd
Mobile : 008615051844186
Phone : 00862584677741
More Information : View
Online order registration form
No comments have been posted yet
loading
Your comment has been sent
Small Oxygen Plant

Advantage
1. Especally designed for clinics and small hospitals up to100 beds.
2. Small size and occupy small area
3. Easy installation.
4. The design is made for 24/7 operation.It is a strong system.
5. Convenient maintenance and low maintenance cost.
6. Equipped with automatic start&stop function.Safer and more reliable design.Humanization design. More longer equipment life.
7. Total oil free system, safer and healthier.
8. Easy operation.
9. Economic system to meet small hospitals low investment requirement

How to calculate what kinds of system a hospital needs?
All solutions depending on we know about the hospital requirement very well.
For example, how many patient beds? if there is ventilator or anesthesia machine?
After we learn about these information, we can provide a solution with below formula.
- An ordinary hospital bed requires 3L of oxygen with pressure within 1 bar/0.1Mpa, and 60% utilization.
- If it is an ICU bed, each bed needs 5L with pressure within 1 bar/0.1Mpa, 100% utilization
- One anesthesia machine with 20L oxygen under pressure 4bar /0.4Mpa;
- One ventilator with 10L oxygen under pressure 4bar /0.4Mpa.
- For cylinder filling. we count it as 24 hrs working continuously and the cylinder tank 40L(150bar).
For example, an JAY-60 can fufill 12 cyliners in 24 hrs.
We count it as 40L *150 bar / 60L =100min. It takes approximately 2 hrs to fufill 1 tank.

Below are some of our solutions, we can customize solution according to your actual requirement

Saler Company Information

Company : Pioway Medical Lab Equipment Co., Ltd
Mobile : 008615051844186
Phone : 00862584677741
More Information : View
Online order registration form