WS-B Series Horizontal Sterilizer
WS-B Series Horizontal Sterilizer
  • Seen : 223 View

0
WS-B Series Horizontal Sterilizer

1.Sterilizing course automatic sterilization controlled by computer, easy to operate.
2.With drying function, suitable dressing drying.
3.With over-temperature, over-pressure auto-protect device.
4.The door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027MPa.It can't be start on if the doesn't closed well.
5.The safety value will be open automatically when the inner pressure over 0.24MPa, and the steam be exhausting to the water tank.
6.The power will be cut-off automatically, cut-off the water and alarm when the machine lacking water. 7.The chamber of the sterilizer is made of stainless steel.
8.With printer.
TECHNICAL DATA:

Technical data

WS-150B

WS-200B

WS-280B

Sterilizing chamber Volume

150L φ 440 × 1000mm

200L φ 515 × 1000mm

280L φ 600 × 1000mm

working pressure

0.22 MPa

working  temperature

134 °C

Adjustment of temperature

40   - 134 °C

Time of sterilization

0-99 min

Time of drying

0-99 min

Heat average

< ± 2 °C

Power

9KW/380V 50Hz

9KW/380V 50Hz

12KW/380V 50Hz

Dimension

1400 × 650 × 1600

1400 × 750 × 1700

1520 × 910 × 1900

Transport dimension

1560 × 820 × 1820

1560 × 910 × 1880

1680 × 1080 × 2100

G.W/N.W

430/340 KG

436/350 KG

570/462 KG

Saler Company Information

Company : Nanjing Audo Medical Equipment Co., Ltd
Mobile : 008618726023851
More Information : View
Online order registration form
No comments have been posted yet
loading
Your comment has been sent
WS-B Series Horizontal Sterilizer

1.Sterilizing course automatic sterilization controlled by computer, easy to operate.
2.With drying function, suitable dressing drying.
3.With over-temperature, over-pressure auto-protect device.
4.The door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027MPa.It can't be start on if the doesn't closed well.
5.The safety value will be open automatically when the inner pressure over 0.24MPa, and the steam be exhausting to the water tank.
6.The power will be cut-off automatically, cut-off the water and alarm when the machine lacking water. 7.The chamber of the sterilizer is made of stainless steel.
8.With printer.
TECHNICAL DATA:

Technical data

WS-150B

WS-200B

WS-280B

Sterilizing chamber Volume

150L φ 440 × 1000mm

200L φ 515 × 1000mm

280L φ 600 × 1000mm

working pressure

0.22 MPa

working  temperature

134 °C

Adjustment of temperature

40   - 134 °C

Time of sterilization

0-99 min

Time of drying

0-99 min

Heat average

< ± 2 °C

Power

9KW/380V 50Hz

9KW/380V 50Hz

12KW/380V 50Hz

Dimension

1400 × 650 × 1600

1400 × 750 × 1700

1520 × 910 × 1900

Transport dimension

1560 × 820 × 1820

1560 × 910 × 1880

1680 × 1080 × 2100

G.W/N.W

430/340 KG

436/350 KG

570/462 KG