Vascular Doppler Detector ME520 Monitor
Vascular Doppler Detector ME520 Monitor
  • Seen : 101 View

0
Vascular Doppler Detector ME520 Monitor

Vascular Doppler Detector ME520 Monitor
Product Compatibility:
Me520 Ultrasound Vascular Doppler Detector issuitable for Urology, male, hand surgery, Department of orthopedics, trauma surgery, vascular surgery, burns, plastic surgery, Cardiothoracic Surgery and so on with ultra high sensitivity, small size and easy-to-use characteristics.

ME520 Detectoris mainly used to detect the blood flow status of human or animal artery.

Specification :

Input voltage: DC 9V 1000mA
Doppler frequency: 100--7000Hz
Display: LED 20bit
Working temperature: 10-40℃
Humidity: ≤80%
Atmospheric pressure: 86--106kPa
Feature :

1.ME520 Detectorcan be used to listen the temporo-mandibular joints (They become noisy when they start to brake because of the bite problems), assist doctor to check the conditions of the joints and predict the result of treatment.

2.Detect blood stream status of arterial/venous by 8.0MHz; detect the blood flow average velocity, detect the result of finger/toes and part of body's vein anatomies operation.Bar LED can detect the blood stram status.Ultrasonic probe:8.0MHz±10%

3.Detect phlebostenosis, vein occlusions

4.Detect Systolic pressure of toes and fingers

5.Detect blood speed during recovery

6.Delect the pulse rate and show PR simultaneously

Saler Company Information

Company : Shanghai MedEco Industry Co., Ltd
Mobile : 008613761409730
Phone : 00862132509306
More Information : View
Online order registration form
No comments have been posted yet
loading
Your comment has been sent
Vascular Doppler Detector ME520 Monitor

Vascular Doppler Detector ME520 Monitor
Product Compatibility:
Me520 Ultrasound Vascular Doppler Detector issuitable for Urology, male, hand surgery, Department of orthopedics, trauma surgery, vascular surgery, burns, plastic surgery, Cardiothoracic Surgery and so on with ultra high sensitivity, small size and easy-to-use characteristics.

ME520 Detectoris mainly used to detect the blood flow status of human or animal artery.

Specification :

Input voltage: DC 9V 1000mA
Doppler frequency: 100--7000Hz
Display: LED 20bit
Working temperature: 10-40℃
Humidity: ≤80%
Atmospheric pressure: 86--106kPa
Feature :

1.ME520 Detectorcan be used to listen the temporo-mandibular joints (They become noisy when they start to brake because of the bite problems), assist doctor to check the conditions of the joints and predict the result of treatment.

2.Detect blood stream status of arterial/venous by 8.0MHz; detect the blood flow average velocity, detect the result of finger/toes and part of body's vein anatomies operation.Bar LED can detect the blood stram status.Ultrasonic probe:8.0MHz±10%

3.Detect phlebostenosis, vein occlusions

4.Detect Systolic pressure of toes and fingers

5.Detect blood speed during recovery

6.Delect the pulse rate and show PR simultaneously

Saler Company Information

Company : Shanghai MedEco Industry Co., Ltd
Mobile : 008613761409730
Phone : 00862132509306
More Information : View
Online order registration form