Intelligent reactive power compensation controller is new generation product, to meet development requirements of automatic reactive power compensation.It is used with our intelligent capacitor, with simple wiring , reliable running characteristics.etc. It can real-time show the RS485 interface, power factor, voltage, current, reactive power and other electrical parameters, and intelligent capacitor sets and cutting state, make it very simple, at the same time can save a lot of wiring.

二、Main fuction.

1.CONTROL FUCTION.

(1)Auto,manual control

(2)Automatic switching on-off control be carried according to the controlled parameters (power factor, reactive power, power distribution, current, voltage)

(3)Same volume capacitor based on the principles of cycle to switch on-off control, different volume capacitor control base on reactive power gaps.

(4)predict switching distribution reactive compensation before switching, if it as predicting, and need opposite practicing, then no switching, it can prevent oscillation;

2.Fuction setting

(1)transformation ratio setting

(2)Delay time setting

(3)The power factor setting

(4)protection setting value setting

3.Measurement fuction.

Distribution voltage, current, power factor, reactive power measurement

4.Communications functions

Capacitor operation, return status and way;

5.Protection function

(1)Overvoltage, undervoltage, and loss of pressure protection;

(2)Oscillation protection

三、Main Data

1.work environment

(1) Temperature: - 45 ℃ ~ 55 ℃.

(2) Relative humidity: At 40 ℃ 20 ~ 90%;

(3)Atmospheric pressure: 79.5 ~ 106.0 kpa.

(4) Altitude: not more than 2000 m;

2. Working power supply

(1) Working voltage ac 50 hz, 380 v + / - 20%;

(2) Power consumption: Less than 3 va;

(3) Current sampling: communication 0 ~ 5 a;

3.Measurement accuracy

(1) voltage: 0.5 Grade

(2) Current: 0.5 grade

(3) Reactive power: 1.0 grade

(4) Power factor: ±0.01

4. Volume control

(1) three-phase compensation: ≤28 units;

(2) split phase compensation: ≤14 units

(3) Hybrid compensation: ≤42 units (three phase type 28 units + split-phase 14units)

5. Appearance and installation dimensions

Dimension (width*deep*hight): 120mm×120mm×88mm

Installation hole size (width x height) : 113 mm * 113 mm

四、Machinery installation and electrical wiring

Machinery installation: open a 113 mm x 113 mm square hole in screen, push the device from the screen front into the square hole, inserted the fasteners in the installation groove, tighten the screws to fixed the device on the screen.

Electrical wiring: electrical connection shown below photo. Request correct wiring.

Saler Company Information

Company : Taizhou Huifeng Electron Co., Ltd
Mobile : 008657686331676
Phone : 008613968649796
More Information : View
Online order registration form
No comments have been posted yet
loading
Your comment has been sent
intelligent reactive power compensation controller, Control instrument

Intelligent reactive power compensation controller is new generation product, to meet development requirements of automatic reactive power compensation.It is used with our intelligent capacitor, with simple wiring , reliable running characteristics.etc. It can real-time show the RS485 interface, power factor, voltage, current, reactive power and other electrical parameters, and intelligent capacitor sets and cutting state, make it very simple, at the same time can save a lot of wiring.

二、Main fuction.

1.CONTROL FUCTION.

(1)Auto,manual control

(2)Automatic switching on-off control be carried according to the controlled parameters (power factor, reactive power, power distribution, current, voltage)

(3)Same volume capacitor based on the principles of cycle to switch on-off control, different volume capacitor control base on reactive power gaps.

(4)predict switching distribution reactive compensation before switching, if it as predicting, and need opposite practicing, then no switching, it can prevent oscillation;

2.Fuction setting

(1)transformation ratio setting

(2)Delay time setting

(3)The power factor setting

(4)protection setting value setting

3.Measurement fuction.

Distribution voltage, current, power factor, reactive power measurement

4.Communications functions

Capacitor operation, return status and way;

5.Protection function

(1)Overvoltage, undervoltage, and loss of pressure protection;

(2)Oscillation protection

三、Main Data

1.work environment

(1) Temperature: - 45 ℃ ~ 55 ℃.

(2) Relative humidity: At 40 ℃ 20 ~ 90%;

(3)Atmospheric pressure: 79.5 ~ 106.0 kpa.

(4) Altitude: not more than 2000 m;

2. Working power supply

(1) Working voltage ac 50 hz, 380 v + / - 20%;

(2) Power consumption: Less than 3 va;

(3) Current sampling: communication 0 ~ 5 a;

3.Measurement accuracy

(1) voltage: 0.5 Grade

(2) Current: 0.5 grade

(3) Reactive power: 1.0 grade

(4) Power factor: ±0.01

4. Volume control

(1) three-phase compensation: ≤28 units;

(2) split phase compensation: ≤14 units

(3) Hybrid compensation: ≤42 units (three phase type 28 units + split-phase 14units)

5. Appearance and installation dimensions

Dimension (width*deep*hight): 120mm×120mm×88mm

Installation hole size (width x height) : 113 mm * 113 mm

四、Machinery installation and electrical wiring

Machinery installation: open a 113 mm x 113 mm square hole in screen, push the device from the screen front into the square hole, inserted the fasteners in the installation groove, tighten the screws to fixed the device on the screen.

Electrical wiring: electrical connection shown below photo. Request correct wiring.