UL 2808 (XOBA)Split Core Current Transformer 333mV
UL 2808 (XOBA)Split Core Current Transformer 333mV
  • Seen : 221 View

0
UL 2808 (XOBA)Split Core Current Transformer 333mV

The JIANGYIN SPARK series of split core current transformer are designed for fast and easy installation.The split core design permits non-contact current measurements through magnetic field induction without requiring that the primary wire be taken offline and disconnected for CT installation.This method permits a safer,easy and portable current measurement. An internal precision burden resistor across the secondary winding of the CT provides a safe low voltage output and permits safe opening of the secondary.

Features

Low cost.
Split core design;safer,easier installation,portable.

Specifications

Rated Current 5A to 3000A loads.
Rated output: 0.333Vac
Accuracy:±1% from 5% to 120% of rated current
Phase Angle: less than 2 degrees at 50% of rated current
Insulation Voltage:600Vac
Maximum Primary Voltage:5000Vac(Insulated Conductor)
Operating Temperature:-35℃to 65℃.
Frequency Range:50-400Hz
Leads:4Foot(105cm),UL 1015,Twisted Pair,20AWG
UL&CE recognized. RoHS Compliant,UL file number:E341727
Output and leads can be customized

Saler Company Information

Company : Jiangyin Spark Electronic Technology Co., Ltd
Mobile : 008613771281483
Phone : 008651086271733
More Information : View
Online order registration form
No comments have been posted yet
loading
Your comment has been sent
UL 2808 (XOBA)Split Core Current Transformer 333mV

The JIANGYIN SPARK series of split core current transformer are designed for fast and easy installation.The split core design permits non-contact current measurements through magnetic field induction without requiring that the primary wire be taken offline and disconnected for CT installation.This method permits a safer,easy and portable current measurement. An internal precision burden resistor across the secondary winding of the CT provides a safe low voltage output and permits safe opening of the secondary.

Features

Low cost.
Split core design;safer,easier installation,portable.

Specifications

Rated Current 5A to 3000A loads.
Rated output: 0.333Vac
Accuracy:±1% from 5% to 120% of rated current
Phase Angle: less than 2 degrees at 50% of rated current
Insulation Voltage:600Vac
Maximum Primary Voltage:5000Vac(Insulated Conductor)
Operating Temperature:-35℃to 65℃.
Frequency Range:50-400Hz
Leads:4Foot(105cm),UL 1015,Twisted Pair,20AWG
UL&CE recognized. RoHS Compliant,UL file number:E341727
Output and leads can be customized

Saler Company Information

Company : Jiangyin Spark Electronic Technology Co., Ltd
Mobile : 008613771281483
Phone : 008651086271733
More Information : View