Industrial ultrasonic gas meter
Industrial ultrasonic gas meter
  • Seen : 537 View

0
Industrial ultrasonic gas meter

The method of measuring the industrial ultrasonic contour is based on the measurement of the changes of the ultrasonic signal timing between the two transducers. In this method, a pair of transducers is positioned opposite each other on either side of the fluid passage (the so-called transducer path). When the flow rate is zero, the signal transient time between the two transducers is equal to the two transverse directions (so-called high and low transient). As the flow changes, the difference between the up and down transition time changes according to the amount and direction of the flow; this difference is the basis for calculating the flow velocity and the flow. Because of the uneven fluid velocity profile at the contour cross-section and for increased measurement accuracy, the number of transducer paths is usually chosen as 3 or 4 paths.
Industrial ultrasonic contactors are manufactured by Gas Burner Company with 4 transducer paths in sizes 4 to 12 inches and 150, 300 and 600 working classes. Among the benefits of these contours can be the design of Intrinsically Safe (whole electronic system, safe from explosion), high precision (half to one percent error), low maintenance cost (due to the absence of circular mechanical parts that are damaged or corroded). ) And a variety of communication ports (USB- RS485- MODBUS- HART- Digital Output)

Saler Company Information

Company : GAS SOUZAN
More Information : View
Online order registration form
No comments have been posted yet
loading
Your comment has been sent
Industrial ultrasonic gas meter

The method of measuring the industrial ultrasonic contour is based on the measurement of the changes of the ultrasonic signal timing between the two transducers. In this method, a pair of transducers is positioned opposite each other on either side of the fluid passage (the so-called transducer path). When the flow rate is zero, the signal transient time between the two transducers is equal to the two transverse directions (so-called high and low transient). As the flow changes, the difference between the up and down transition time changes according to the amount and direction of the flow; this difference is the basis for calculating the flow velocity and the flow. Because of the uneven fluid velocity profile at the contour cross-section and for increased measurement accuracy, the number of transducer paths is usually chosen as 3 or 4 paths.
Industrial ultrasonic contactors are manufactured by Gas Burner Company with 4 transducer paths in sizes 4 to 12 inches and 150, 300 and 600 working classes. Among the benefits of these contours can be the design of Intrinsically Safe (whole electronic system, safe from explosion), high precision (half to one percent error), low maintenance cost (due to the absence of circular mechanical parts that are damaged or corroded). ) And a variety of communication ports (USB- RS485- MODBUS- HART- Digital Output)

Saler Company Information

Company : GAS SOUZAN
More Information : View
Online order registration form